HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
Ähnliche Produkte
1/15
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATH...
DE-72175 Dornhan
RE-2Y(St)H-TIMF & RE-2X(St)H-TIMF
RE-2Y(St)H-TIMF & RE-2X(St)H-TIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H-T...
DE-72175 Dornhan
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H
RE-2Y(St)H & RE-2X(St)H
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & M...
DE-72175 Dornhan
RE-2Y(St)Y-fl-TIMF & RE-2X(St)Y-fl-TIMF
RE-2Y(St)Y-fl-TIMF & RE-2X(St)Y-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl-TIMF,MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl-TIMF,MULT...
DE-72175 Dornhan
RE-2Y(St)2YSWAY-fl-TIMF
RE-2Y(St)2YSWAY-fl-TIMF
INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cable...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H MP
RE-2Y(St)H & RE-2X(St)H MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MUL...
DE-72175 Dornhan
RE-2Y(St)Y-fl
RE-2Y(St)Y-fl
INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H-MP
RE-2Y(St)H & RE-2X(St)H-MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MUL...
DE-72175 Dornhan
RE-2G(St)HSWAH-CI-TIMF  FE180
RE-2G(St)HSWAH-CI-TIMF FE180
HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-TRIPLE, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR ...
DE-72175 Dornhan
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl
INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PVC INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of a...
DE-72175 Dornhan
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZ...
DE-72175 Dornhan
RE-2Y(St)HSWAH&RE-2X(St)HSWAH
RE-2Y(St)HSWAH&RE-2X(St)HSWAH
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATH...
DE-72175 Dornhan
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED...
DE-72175 Dornhan
RE-2G(St)HSWAH-CI-PIMF  FE180
RE-2G(St)HSWAH-CI-PIMF FE180
HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SH...
DE-72175 Dornhan
Trend-Produkte
1/15
Altreifenentsorgung
Altreifenentsorgung
LIW Lausitzer Industrieruß Werke GmbH
DE-03172 Guben
Ankauf von gebrauchten Schuhen
Ankauf von gebrauchten Schuhen
VERSERO GmbH
DE-13127 Berlin
GLS  Sendungsverfolgung
GLS Sendungsverfolgung
Meine Sendungsverfolgung
DE-18439 Stralsund
Hanf Samen
Hanf Samen
Less Organix Inh. Christoph Lesser
DE-97437 Haßfurt
Münz-Ankauf-Service
Münz-Ankauf-Service
ESG Edelmetall-Service GmbH & Co KG
DE-76287 Rheinstetten
Kaminofen kaufen
Kaminofen kaufen
Feuer hoch 3
DE-86500 Kutzenhausen
Wagen aus Holz
Wagen aus Holz
HBU GmbH
DE-19230 Bobzin
IVG2400 Pods Großhandel ab 4,50€
IVG2400 Pods Großhandel ab 4,50€
Andreas Shimf
DE-21031 Hamburg
CBD Gel (600mg) - 30ml für Muskel & Gelenke
CBD Gel (600mg) - 30ml für Muskel & Gelenke
Less Organix Inh. Christoph Lesser
DE-97437 Haßfurt
HHC/THCP/CBG9 Großhandel
HHC/THCP/CBG9 Großhandel
Andreas Shimf
DE-21031 Hamburg
Werkzeugfräsmaschine Deckel FP3-aktiv
Werkzeugfräsmaschine Deckel FP3-aktiv
Franz Singer Werkzeugmaschinen GmbH
DE-82538 Geretsried / Gelting
Neue Eichen-Schwellen - Eisenbahnschwellen
Neue Eichen-Schwellen - Eisenbahnschwellen
Baka-Holz Holzgroßhandel für den Gartenbau GmbH
DE-46238 Bottrop